6666IMPORTANT SPA INFORMATIONIMPORTANT: In areas where the ambient temperature falls below 20°F, and you do not want to winterize your spa, it is reco
777II. INSTALLATION INSTRUCTIONSSITE PREPARATIONYou probably have a spot picked out for your new spa, whether it’s indoors or outdoors, on a patio or
INDOOR/BASEMENT INSTALLATIONBe aware of some special requirements if you place your spa indoors. Water will accumulate around the spa, so flooring mat
9999Deck InstallatIonTo be certain your deck can support your spa, you must know the deck’s maximum load capacity. Consult a qualified building contra
10101010•Removethesixscrewcaps- Place a flat head screwdriver between the panel and the screw cap, then carefully rotate the screwdriver to remo
your local city government office.2. IMPORTANT: The spa is designed for installation on a relatively flat and level surface. Installing the spa on a
the rounded side, until a level reading is achieved. These are now your preselected shims.4. Carefully remove the carpenter’s level and the sets of s
13131313ELECTRICAL REQUIREMENTS AND PRECAUTIONSge n e r a l in f o r m a t i o nIMPORTANT: On Canadian spas, CSA requirements for Canadian spas do no
•Converted (hard-wired) 115 volt, 30 amp – A minimum 30 amp circuit breaker in the house breaker panel, #10-AWG or larger wire (including the ground
co n v e r t e d 115 vo l t , 30 am P co n f i g u r a t i o n co n v e r s i o n i n s t r u c t i o n sNOTE: An Authorized Solana® Spa Technicia
Watkins Manufacturing CorporationOwner’s ManualThis Owner’s Manual will acquaint you with your new spa’s operation and general maintenance. We suggest
30 am p s u b -p a n e l w i ring i n s t r u c t i o n s NOTE: The sub-panel must be placed within 100 feet of the main electrical service panel,
5. Inside the control panel, locate the terminal block (TB-1).6. Remove existing power cord.7. Connect the #10 AWG, BLACK wire from the sub-panel 3
18NOTE:- Jumpers are located in top right corner of Control Box labeled P4 “Config Jumpers”- To Change from fahrenheit to celsius remove jumper
50 am p (optional) s u b -p a n e l w i r i ng i n s t r u c t i o n s NOTE: The sub-panel must be placed within 100 feet of the main electrical se
202020202020TX SPA SPECIFICATIONSHORIZONTAL DIMENSIONS: ...67” x 67” (170 cm x 170 cm)HEIGHT (without cover):...29” (74 cm)EFFECTIVE FILTER AREA
212121212144443521TX EQUIPMENT COMPARTMENT VIEW1. 1.0 kW Heater2. Spa Drain Valve3. Electrical Control Box4. Compression Unions5. Jet Pump (Wav
2222222222SX SPA SPECIFICATIONSHORIZONTAL DIMENSIONS: ...72” (183 cm.) squareHEIGHT (without cover):...33” (83.8 cm)EFFECTIVE FILTER AREA: ...
23232323SX EQUIPMENT COMPARTMENT VIEW1. 1.0 kW Heater2. Spa Drain Valve3. Electrical Control Box4. Compression Unions5. Jet Pump (Wavemaster® 6
2424242424III. OPERATING INSTRUCTIONSSTART-UP AND REFILL PROCEDURESYour Solana® spa has been thoroughly tested during the manufacturing process to ens
252525253. The jet pump, heating system and all internal plumbing will achieve a partial prime as the spa is filled. To check the operation of the je
Pu r c h a s e i n f o r m a t i o nDATE PURCHASED: ____________________________________________DATE INSTALLED: ____________________________________
2626262626OPERATION NOTES:1. The Solana® spa is equipped with a 10-minute Tranquil Mode timer delay on the heating/maintenance mode. Whenever the hig
27272727Under normal conditions, the heater and low-speed cycle will run 2-4 times per day for approximately 20 minutes per cycle. If the ambient temp
2828282828the filter Icon will blink for the remaining filter cycle time. Should the temperature cool down to 1.5 degrees F below the set point before
29Temp Up (▲) & Temp Down (▼) buttons together for 3 seconds again.LOCKING FEATURESThe locking features, TEMPERATURE LOCK and SPA LOCK, are enable
3030303030SERVICE NOTE: A slow or non-moving Moto-Massage jet may indicate that the filter cartridge pores are obstructed with dirt, body oils, or cal
3131to t e s t t h e gfci: Before each use, with the spa operating, push the TEST button (located on the front of the GFCI). The GFCI breaker shoul
3232SPA CONTROL PANELA. JETS BUTTON: Use the JETS button to activate the jet pump. Pushing the JETS button once will activate the jet pump on low spee
3333D. TEMPERATURE CONTROLS: The set temperature range is from 80°F to 104°F (27°C to 40°C). The temperature of any setting may rise slightly dependin
343434343434IV. SPA CARE AND MAINTENANCEYour Solana® spa is manufactured from the highest quality, most durable materials available. Even so, the spa
5. Remove the filter cartridge and clean as required (see the Filter Maintenance section).6. Replace the filter cartridge.7. Close the drain valve
I. SAFETY INFORMATION Important Safety Instructions ...1 Important Spa Information ...5II. IN
3636363636 SERVICE NOTE: Never remove the filter standpipe. Debris may find its way into the internal plumbing which may result in blockage. NEVER RE
3737373737sP a si d i n gThe spa siding of the Solana® TX spa is manufactured from Endurol®, a durable U.V.-resistant material. Even so, monthly clea
38383838382. Rinse off the underside of the cover with water only (do not use soap), and wipe it clean with a dry rag.3. To condition the cover afte
3939393939CARE OF THE SPA PILLOWThe spa pillows will provide years of comfort if treated with care. The pillows have been positioned above the water l
4040404040lo n g ti m e Pe r i o d s (5-14 da y s ):pr i o r t o l e a v i n g :1. At least one day before you leave, set the temperature to 80°
4141414141Drain your spa following the Draining Your Spa section in the owner’s manual. 1. Remove the filter cartridge, clean and store in a dry plac
4242424242Open drain to remove anti-freeze. Replace drain cap.2. Follow the Start-up and Refill Procedures in the Operating Instructions section of th
4343434343Water Sanitation is the responsibility of the spa owner, achieved through the regular and periodic (daily, if necessary) addition of an appr
4444444444•Don’tinhalefumesorallowchemicalstocomeincontactwithyoureyes,nose,ormouth.Washyourhandsimmediatelyafteruse.•Followth
4545454545THE SOLANA® SPA WATER MAINTENANCE PROGRAMEach step in your water maintenance program is dependent on the completion of the previous steps. O
I. SAFETY INFORMATIONIMPORTANT SAFETY INSTRUCTIONSRe a d a n d Fo l l o w al l In s t R u c t I o n sav o i d i n g t h e ri s k t o ch i l d
464646F. When the Total Alkalinity is within the recommended range, proceed to the next step.Ba l a n c i n g t h e ca l c i u m ha r d n e s s (
4747474747Ba l a n c i n g t h e PhA. The ideal pH level for your spa water is 7.4-7.6.B. ThepHlevelisthemeasureofacidityandalkalinity.Va
4848484848* MPS is an oxidizer, not a sanitizer.solana water treatment guideat s p a s t a R t U p o R R e f I l lFollow Start-Up and Refill Proced
4949494949ma i n t a i n i n g t h e sa n i t i z e r le v e lA. Sanitizer is extremely important for killing algae, bacteria and viruses, and prev
5050505050It is important to follow the recommended application and maintenance programs outlined for each product’s use. If the spa is being used ove
51515151514. Locate the filter cap. Turn the filter cap counterclockwise until the cap can be removed from the filter standpipe.5. Remove and clean
5252525252do s a n d do n ’t s•DOcheckyourMPSorSodiumDichlorchemicallevelpriortoeachuse.•DOchangetheFreshWaterAg+ silver ion purifi
5353535353concentrated form of sanitizer WILL damage your spa and is specifically not covered under the terms of the limited warranty. IMPORTANT: Gra
5454545454su P P l e m e n t a l Wa t e r ma i n t e n a n c eProper water sanitation and mineral balance (pH control) are absolutely essential for
The under-the-skirt mounted FreshWater® III high output ozone system unit offers less-visible installation and is less susceptible to the effects of f
2222av o i d i n g t h e ri s k o f el e c t r o c u t i o nDa n g e r : ri s k o f e l e c t r o c u t i o n•Connectonlytoagroundedsource
5656565656565. Carefully loosen the long Tygon / Kynar tubing to the bottom of the ozonator. Aliquidsubstancemaybefoundinsidethetubing.Ifa
5757575757If the dispenser setting is too high, the high concentration can discolor the spa shell and damage the underside of the cover.Automatic floa
585858585858Answer: There are two types of chlorine in your spa. The first is the Free Available Chlorine, which is the chlorine available to sanitize
5959595959Chlorine: An efficient sanitizing chemical for spas. Watkins Manufacturing Corporation recommends the use of Sodium Dichlor-type granulated
606060606060pH control. If the TA is too high, the pH is difficult to adjust. If the TA is too low, the pH will be difficult to hold at the proper lev
6161616161FRESHWATER® III HIGH OUTPUT OZONE SYSTEM (OPTIONAL)The FreshWater III high output ozone system is practically maintenance-free because it is
626262MISCELLANEOUS SERVICE INFORMATIONThe jet pump is equipped with a overload cut-off switch, which is designed to protect the pump from overheating
63byallowingundissolvedspasanitizingchemicalstolieonthespasurface(nospasurfacematerialcanwithstandthiskindofabuse);damagetocom
6464(continued on next page)pR o b l e mpR o b a b l e C a U s e sso l U t I o n sEntire spa is inoperative• P
656565656565Problem Probable causes SolutionsCloudy Water• Dirtyfilters• Excessiveoils/organicmatter
333snap into the “tripped” position and the spa should stop operating. Reset the sub-panel GFCI breaker by completely flipping the breaker switch down
67
WATKINS MANUFACTURING CORPORATIONVISTA, CALIFORNIAUSAThis manual contains installation, operating, maintenance and service information for the followi
4444ri s k s t o av o i dDa n g e r : ri s k o f in j u r y•Toreducetheriskofinjurytopersons,DONOTremovesuctionfittings(filterstand
555•Cleanthefiltercartridgemonthlytoremovedebrisandmineralbuildupwhichmayaffecttheperformanceofthehydromassagejets, limit the flow